2 - OPERATION
Defaults and Alarms
The tables below give the default values of severity associated with the failures.
Alarms | Description | Severity |
SPI : SDH Physical Interface |
| |
LOS | Loss Of Signal- | Major |
|
|
|
TF | Transmit Fail | Major |
|
|
|
RST : Regenerator Section Termination |
| |
LOF | Loss Of Frame | Major |
|
|
|
MST : Multiplex section Termination |
| |
Bit Error Rate > | major | |
|
|
|
Signal Degrade | minor | |
|
|
|
Alarm Indication Signal | ||
|
|
|
Remote Defect Indication | minor | |
|
|
|
MSP : Multiplex Section Protection |
| |
PAM | Protection Architecture Mismatch | minor |
|
|
|
SCM | Selector Control Mismatch | minor |
|
|
|
OTM | Operation Type Mismatch | minor |
|
|
|
MSA : Multiplex Section Adaptation |
| |
Administrative Unit - Alarm Indication Signal | ||
|
|
|
Administrative Unit – Loss Of Pointer | major | |
|
|
|
HPOM : Higher Order path Overhead Monitor |
| |
High Order Path | minor | |
|
|
|
High order Path – Unequipped | ||
|
|
|
HPT : Higher Order Path Termination |
| |
High Order Path | ||
|
|
|
High Order Path | minor | |
|
|
|
High Order Path | ||
|
|
|
HPA : Higher Order Path Adaptation |
| |
Tributary Unit - Loss Of Multiframe | minor | |
|
|
|
Tributary Unit – Alarm Indication Signal | ||
|
|
|
Tributary Unit - Loss Of Pointer | minor | |
|
|
|
LPOM : Lower Order path Overhead Monitor |
| |
Signal Degrade | minor | |
|
|
|
Signal Degrade | minor | |
|
|
|
Low order Path | minor | |
|
|
|
Low order Path – Unequipped | ||
|
|
|
Table 2-9 : Alarms and severity (1/2)
Installation and User Guide - N56717020101