2 - OPERATION

Defaults and Alarms

The tables below give the default values of severity associated with the failures.

Alarms

Description

Severity

SPI : SDH Physical Interface

 

LOS

Loss Of Signal-

Major

 

 

 

TF

Transmit Fail

Major

 

 

 

RST : Regenerator Section Termination

 

LOF

Loss Of Frame

Major

 

 

 

MST : Multiplex section Termination

 

EBER-B2

Bit Error Rate > 10-3on B2 Byte

major

 

 

 

SD-B2

Signal Degrade -B2

minor

 

 

 

MS-AIS

Alarm Indication Signal

Non-alarmed

 

 

 

MS-RDI

Remote Defect Indication

minor

 

 

 

MSP : Multiplex Section Protection

 

PAM

Protection Architecture Mismatch

minor

 

 

 

SCM

Selector Control Mismatch

minor

 

 

 

OTM

Operation Type Mismatch

minor

 

 

 

MSA : Multiplex Section Adaptation

 

AU-AIS

Administrative Unit - Alarm Indication Signal

Non-alarmed

 

 

 

AU-LOP

Administrative Unit – Loss Of Pointer

major

 

 

 

HPOM : Higher Order path Overhead Monitor

 

HO-RDI/G1

High Order Path -Remote Defect Indication

minor

 

 

 

HO-UNEQ

High order Path – Unequipped

Non-alarmed

 

 

 

HPT : Higher Order Path Termination

 

HO-SLM

High Order Path -Signal Label Mismatch

Non-alarmed

 

 

 

HO-RDI/G1

High Order Path -Remote Defect Indication

minor

 

 

 

HO-UNEQ

High Order Path –UNEQuipped

Non-alarmed

 

 

 

HPA : Higher Order Path Adaptation

 

TU-LOM

Tributary Unit - Loss Of Multiframe

minor

 

 

 

TU-AIS

Tributary Unit – Alarm Indication Signal

Non-alarmed

 

 

 

TU-LOP

Tributary Unit - Loss Of Pointer

minor

 

 

 

LPOM : Lower Order path Overhead Monitor

 

SD-B3 (VC3)

Signal Degrade –B3

minor

 

 

 

SD-B2 (VC12)

Signal Degrade –B2

minor

 

 

 

LO-RDI

Low order Path -Remote Defect Indication

minor

 

 

 

LO-UNEQ

Low order Path – Unequipped

Non-alarmed

 

 

 

Table 2-9 : Alarms and severity (1/2)

Installation and User Guide - N56717020101

No reproduction or communication without the written consent of SAGEM SA

Page A2-13

Page 49
Image 49
Sagem ADR 155C manual Defaults and Alarms, SPI SDH Physical Interface, RST Regenerator Section Termination