2 - OPERATION
| Configuration parameters per functional blocks | Default | |
| 
 | value | |
| 
 | 
 | |
| ADRLAN Card – continue | 
 | |
| Interface configuration | 
 | |
| - LAN in service / no service | Service | |
| - Maximum route Age | 300 s | |
| - Path trace J1 transmitted : | "UNNAMED . | |
| "UNNAMED VC3" + CRC7 not configurable and not treated in reception | VC3" + CRC7 | |
| 
 | 
 | |
| SETS : Synchronous Equipment Timing Source | 
 | |
| Quality level of synchronization sources ; "Quality" : | T3 : PRC | |
| - "PRC" (Primary Reference Clock), | ||
| T1 : SSMB | ||
| - "SSUT" (Synchronisation Supply Unit Transit), | ||
| 
 | ||
| - "SSUL" (Synchronisation Supply Unit Local), | T2 : SEC | |
| - "SEC" (Synchronisation Equipment Clock), | T4 : SEC | |
| - "DNU" (Do Not Use), | 
 | |
| - "SSMB" (Synchronisation Status Message Byte) (synchronization quality | 
 | |
| carried out in S1 Byte). | 
 | |
| 
 | 
 | |
| Use of synchronization status messages (SSM) ; | 
 | |
| "SSM" | "ON" | |
| 
 | 
 | |
| T0 priority Table, according to enabled sources ; | "1" | |
| possible values : 1 to 8 | for all sources | |
| 
 | 
 | |
| 2 Mbit/s port number chosen for T2 ; "T2 Tributary port" | "1" | |
| (1 port per enabled 2 Mbit/s card) | 
 | |
| 
 | 
 | |
| Revertive authorization (common to all sources) : return after a WTR time- | 
 | |
| delay to the working link when the fault (SF or SD) causing the switch has | 
 | |
| disappeared. | 
 | |
| "Revertive" | "yes" | |
| 
 | ||
| 
 | 
 | |
| Wait Time to Restore (WTR) period : in revertive mode, period following | 
 | |
| restoration of nominal operation ; configurable from 0 to 30mn by one- | 
 | |
| second step | 
 | |
| "WTR" | "1 mn" | |
| 
 | 
 | |
| Source selected for T4 ; | 
 | |
| "Active source" | "T0" | |
| 
 | ||
| 
 | 
 | |
| SASE mode control (enable or disable) | disabled | |
| 
 | 
 | |
| T3 source selection for SASE mode  | 
 | |
| 
 | 
 | |
| Quality level for T4 | "PRC" | |
| - "PRC" (Primary Reference Clock), | ||
| 
 | ||
| - "SSUT" (Synchronisation Supply Unit Transit), | 
 | |
| - "SSUL" (Synchronisation Supply Unit Local), | 
 | |
| - "SEC" (Synchronisation Equipment Clock), | 
 | |
| 
 | 
 | 
Table 2-4  – Configuration parameters (4/6)
Installation and User Guide - N56717020101
| No reproduction or communication without the written consent of SAGEM SA | Page  | 