| 4 - SPECIFICATIONS |
|
| 4. SPECIFICATIONS |
|
|
|
| EQUIPMENT |
|
|
|
|
| Optical specifications |
|
|
|
|
| Interface type | IC1.1 = L1.1 + S1.1 or IC1.2 = L1.2 + S1.2 |
| Bit rate | 155.520 Mbit/s ± 20 ppm |
| Standard | |
| Encoding | Not encoded (NRZ) |
| Optical fiber | |
|
| |
|
| * : It is possible to use a |
|
| whose diameter is smaller than or equal to 62.5 |
|
| microns |
| Guaranteed attenuation | 0 - 28 dB with no external attenuator |
| Typical range | 0 - 70 km (IC1.1) or 0 - 100 km (IC1.2) |
| Connector | |
| Mechanical specifications |
|
|
|
|
| Height | 2U |
| Width | 19" or ETSI |
| Depth | 300 mm |
| Weight | 6 kg approx. |
| Protection Class (IP) | Corresponding to the IP of the rack used |
| Consumption | < 40 W (to a equipped subrack of two cards |
|
| ADR IC1.x and two cards ADR LAN) |
|
|
|
| Environmental specifications |
|
|
|
|
| Mechanical | ETS 300 |
|
| ETS 300 |
| Climatic conditions | CEI |
|
| ETS300 019 part |
| Operating temperature range | - 5 °C à + 45°C |
| Extended operating temperature | - 25 °C to + 55°C (the MTBF [Mean Time Between |
| range | Failure] is significantly degraded) |
| Packaged transportation and | - 40°C to + 70°C |
| storage temperature |
|
| Relative humidity | < 85% |
| ESD | NF EN |
|
| NF EN |
|
| and ETS 300 |
| EMC (Electromagnetic Compatibility) | NF EN 55022 (1994) |
|
| + Additive A1 02/1996 equipment Class B |
| Safety | NF EN 60950 and UTE C 92130 |
|
| (the equipment does not provide the fire envelope) |
| Energy | ETS |
|
| (is VLV equipment) |
Installation and User Guide - N56717020101
No reproduction or communication without the written consent of SAGEM SA | Page |