1 - INSTALLATION AND COMMISSIONING
Installation and User Guide - N56717020101
Page A1-16 No reproduction or communication without the written consent of
SAGEM SA
1.3.4 - Connecting on ADR LAN1 card
ADR LAN1
ETH 10/100 HALF/FULL
ETH
1 : TX_ETH_TIP 5 : NC2 : TX_ETH_RING 6 : RX_ETH_RING3 : RX_ETH_TIP 7 : NC4 : NC 8 : NC
STATUS
10/100
Yellow LED : Ethernet interface bite rate
ON : 100 Mbit/s
HALF/FULL
Yellow LED : Ethernet interface type
(Half or Full Duplex)
ON : Full duplex
Contact 8Contact 1
NC : Reserved
LED STATUS
Green Red
ON OFF Card in service
ON ON Card in alarm
OFF OFF Hardware defaul t (fuse)
OFF ON Card out of service
Flashing Autotest default
Yellow LED : link status
ON : correct link
Green LED : traffic status
ON : on reception

Figure 1-5 – Connecting ADR LAN1 card input

"ETH" Interface :

Port Traffic Ethernet interface operating at 10 or 100 Mbit/s in half-duplex or full-

duplex mode according to the mode used by the interlocutor (dynamic

adaptation of the Ethernet port on each new log-in of the interlocutor),

Connector Ethernet 10 or 100 BaseT - RJ48 Type (Shielded RJ45).

Pin 8
Pin 1
Front view
Pin N° Signal name Comments
1 TX_ETH_TIP Ethernet output (hot point)
2 TX_ETH_RING Ethernet output (cold point)
3 RX_ETH_TIP Ethernet input (hot point)
4 NC Reserved
5 NC Reserved
6 RX_ETH_RING Ethernet input (cold point)
7 and 8 NC Reserved

NOTE: Two LEDs are linked to the "ETH" interface:

LED, "Activity", green colour : Trafic status indicator,

LED, "Link", yellow colour : Link status indicator.

Electrical characteristics compliant with the IEEE 802.3U