2 - OPERATION

Configuration parameters per functional blocks

Default

 

value

 

 

Equipment – Continue

 

Alarms

 

 

 

Alarm severity

See tables

The severity of each alarm is configurable individually with the following

2-9 to 2-11

 

attributes: major, major reverse, minor, minor reverse, none, none reverse

 

 

 

Alarm Persistence

 

Persistence for the appearance: X = 1, 3, 10 or 30s

X = 3s

Persistence for the disappearance: Y = 01, 3, 10 or 30s

Y = 3s

 

 

Loops

 

 

 

Mismatch of remote indication loops 1 and 2 validated or not

Not validated

(use of bits 1 to 4 of byte S1)

 

 

 

Centre site (yes/no)

No

 

 

Routing

 

 

 

Authorization to transmit traps to the management: declaration of the

 

manager addresses (10 addresses possible)

 

 

 

Tables of configured static routes

Not configured

 

 

Putting ports into service: Ethernet, PPP1, PPP2, PPP3 or PPP4

 

Enabled / Disabled (port by port)

Disabled

 

 

Port addressing (port by port) :

 

Interface IP address

0.0.0.0

Subnetwork mask

0.0.0.0

Destination IP address (PPP interface only)

0.0.0.0

 

 

Management paths (port by port – PPP only):

 

Options: MNGT, DCC1_A, DCC1_B, DCC1_C, DCC1_D

Not configured

 

 

RIP routing validated or not (port by port)

Not validated

 

 

Table 2-6 – Configuration parameters (6/6)

Installation and User Guide - N56717020101

No reproduction or communication without the written consent of SAGEM SA

Page A2-7

Page 43
Image 43
Sagem ADR 155C manual Configuration parameters 6/6