2 - OPERATION

Configuration parameters per functional blocks

Default

 

value

 

 

OHA : OverHead Access

 

EOW interface operating mode :

 

CO (codirectional) or CT (contra-directional master)

 

"EOW configuration"

CT

 

 

Selection of E1/E2"

E1

 

 

AUX interface operating mode (F1);

 

CO (codirectional) or CT (contra-directional master)

 

"AUX configuration"

CT

 

 

MCF : Message Communications Function

 

MNGT interface operating mode ;

 

CO (codirectional) or CT (contra-directional master)

 

"P port configuration"

CO

 

 

Equipment

 

Session

 

Selection of clearance level :

 

Administrator

Admin

Operator

 

Observer

 

 

 

One password by clearance level

No password

(Only the administrator may modify password)

 

 

 

Equipment date and time

"01/01/1970"

 

 

Status of slots A, B, C, D (slot configured with an expected card)

A, C:ADR21E120

B, D : ADRIC1.x

 

 

 

Monitoring

 

 

 

Monitoring of modules

No Monitoring

A no-monitored card is indicated in the equipment view; not monitoring a

 

card inhibits the entire management of the faults related to this card (card

 

and port)

 

 

 

Subrack Monitoring

Monitoring

 

 

Monitoring of ports

Monitoring

Not monitoring a port inhibits the entire management of the faults related to

for physical port

this port

No Monitoring

 

 

for performance

 

 

Putting a card into/out of service

Service

(The card is ignored by the management function)

 

 

 

Table 2-5 – Configuration parameters (5/6)

Installation and User Guide - N56717020101

Page A2-6

No reproduction or communication without the written consent of SAGEM SA

Page 42
Image 42
Sagem ADR 155C manual EOW configuration, AUX configuration, Port configuration, Admin, 01/01/1970, No Monitoring