2 - OPERATION

2.6 - Performance processing

Performance processing consists in supervising the following monitoring ports:

for local equipment:

regeneration section (byte B1) ("near end working (protection) RS"), multiplex section (byte B2) ("near end working (protection) MS"),

SVC3 tributary paths ("near end Low Path Virtual Container"),

VC12 tributary paths (byte V5) ("near end Low Path Virtual Container"),

for the remote equipment:

multiplex section (byte M1) ("far end working (protection) MS"), VC3 tributary paths ("far end Low Path Virtual Container")

VC12 tributary paths (byte V5) ("far end Low Path Virtual Container").

Performance processing includes the following functions:

calculation of the number of errored blocks (or bit errors) on local and remote faults and monitoring of the appearance faults over a one second period (VC12-REI indicators are not taken into account in the calculation),

calculation and determination of the ES (Errored Second), SES (Severely Errored Second), BBE (Background Block Error) and UAS (UnAvailable Second) states for each monitoring

Spoint,

generation for each monitoring point of 15-minute counters and 24-hour counters (BBE, ES, SES and UAS).

Determination of ES, SES and UAS performance states:

For each of the monitoring points, the following states are:

- ES (Errored Second)

: number of seconds with at least one error detected

 

in a 1 s period or one fault,

- SES (Severely Errored Second)

: number of severely errored seconds,

An SES is a second for which the number of errors exceeds a defined threshold or during which at least one fault is detected.

 

Monitoring point

 

SES declaration threshold

 

 

 

 

MS (byte B2) (for local) and MS (byte M1) (for remote)

2400

 

 

 

 

 

RS (byte B1) (for local)

 

2400

 

 

 

 

 

VC3 (for local)

 

600

 

 

 

 

 

VC12 (byte V5) (for local)

 

600

 

 

 

 

- UAS (UnAvailable Second)

: number of seconds of unavailability,

- BBE (Background Block Error)

: number of residual errored blocks excluding SES.

Installation and User Guide - N56717020101

No reproduction or communication without the written consent of SAGEM SA

Page A2-17

Page 53