2 - OPERATION
Correlation of faults
A correlation mechanism is implemented on all faults detected.
This correlation mechanism, implemented on each change of information collected, is used to eliminate faults induced by other faults to facilitate fault finding and fault locating.
The following tables define the faults that are masked for each fault detected in the system..
Key :
X: The fault concerned on the current line is masked by the fault in the current column.
For example: The LOF fault is masked by fault 2 (LOS).
Correlation of STM1 faults
|
| FAULTS | 1 |
| 2 |
| 3 | 4 | 5 |
| 6 | |
|
| FAULTS | TF |
| LOS | LOF | AIS | RDI | ||||
| 1 | TF |
|
|
|
|
|
|
|
|
|
|
| 2 | LOS |
|
|
|
|
|
|
|
|
|
|
| 3 | LOF |
|
| X |
|
|
|
|
|
| |
| 4 | AIS |
|
| X | X |
|
|
|
|
| |
| 5 |
|
| X | X | X |
|
|
| |||
| 6 | RDI |
|
| X | X | X |
|
|
| ||
Correlation of MSP faults |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| FAULTS |
| 1 |
|
| 2 |
|
| 3 |
|
|
|
| FAULTS | PAM |
| SCM |
|
| OTM |
|
| ||
| 1 | PAM |
|
|
|
|
|
|
|
|
|
|
| 2 | SCM |
| X |
|
|
|
|
|
|
| |
| 3 | OTM |
| X |
|
|
|
|
|
|
|
Correlation of AU faults
The AU faults are masked by the STM1 LOS, LOF and AIS
The
| FAULTS | 1 | 2 | 3 | 4 | 5 | 6 |
| FAULTS | UNEQ | RDI | SLM | |||
1 |
|
|
|
|
|
| |
2 |
|
|
|
|
|
| |
3 | UNEQ (VC4 UNEQ) | X | X |
|
|
|
|
4 | RDI (VC4 RDI) | X | X | X |
|
|
|
5 | SLM | X | X | X |
|
|
|
6 | X | X | X |
| X |
|
Installation and User Guide - N56717020101