2 - OPERATION

2.2 - General

The ADR155C operation and maintenance are carried out:

-either directly on the equipment, through the front panel indicator lights and two engineering management loops (loops A and B),

-or from a PC fitted with HTTP navigator,

-or from a network manager, using the SNMP protocol.

2.3- Operational parameters

The operational parameters include:

the configuration parameters,

the maintenance commands or operations (these actions are cleared in case of power supply

Sloss)

the alarms and their severity.

Configuration parameters

NOTE : The functional blocks naming, configuration parameters and their default value, noted "XXXXXX", are displayed on HTTP navigator.

Configuration parameters per functional blocks

Default

 

value

 

 

SPI : SDH Physical Interface

 

The Automatic Laser Shutdown function is always enabled

 

(equipment global functionality)

 

"ALS" (Automatic Laser Shutdown)

"enable"

 

 

MST : Multiplex section Termination

 

EBER-B2 monitoring ; configurable in "Monitoring" or "No Monitoring"

" Monitoring"

If EBER-B2 is not monitoring, AIS, SF and MS-RDI consequent actions are

 

inhibited

 

 

 

SD-B2 threshold: configurable from 10-6to 10-9

 

"SD-B2 threshold"

"10-6"

MSP : Multiplex Section Protection

 

Link type : 1+0 or 1+1

"1+0"

 

 

Protection mode : bi-directional / unidirectional

 

"Mode "

"BIDIR"

 

 

Revertive authorization : return after a WTR time-delay to the working link

 

when the fault (SF or SD) causing the switch has disappeared.

 

"Revertive"

 

 

"OFF"

Table 2-1 – Configuration parameters (1/6)

Installation and User Guide - N56717020101

Page A2-2

No reproduction or communication without the written consent of SAGEM SA

Page 38
Image 38
Sagem ADR 155C manual Operational parameters, Monitoring, SD-B2 threshold, Mode, Revertive OFF Configuration parameters 1/6