2 - OPERATION
2.2 - General
The ADR155C operation and maintenance are carried out:
-either directly on the equipment, through the front panel indicator lights and two engineering management loops (loops A and B),
-or from a PC fitted with HTTP navigator,
-or from a network manager, using the SNMP protocol.
2.3- Operational parameters
The operational parameters include:
the configuration parameters,
the maintenance commands or operations (these actions are cleared in case of power supply
Sloss)
the alarms and their severity.
Configuration parameters
NOTE : The functional blocks naming, configuration parameters and their default value, noted "XXXXXX", are displayed on HTTP navigator.
| Configuration parameters per functional blocks | Default | 
| 
 | value | 
| 
 | 
 | 
| SPI : SDH Physical Interface | 
 | 
| The Automatic Laser Shutdown function is always enabled | 
 | 
| (equipment global functionality) | 
 | 
| "ALS" (Automatic Laser Shutdown) | "enable" | 
| 
 | 
 | 
| MST : Multiplex section Termination | 
 | 
| " Monitoring" | |
| If  | 
 | 
| inhibited | 
 | 
| 
 | 
 | 
| 
 | |
| 
 | |
| MSP : Multiplex Section Protection | 
 | 
| Link type : 1+0 or 1+1 | "1+0" | 
| 
 | 
 | 
| Protection mode :  | 
 | 
| "Mode " | "BIDIR" | 
| 
 | 
 | 
| Revertive authorization : return after a WTR  | 
 | 
| when the fault (SF or SD) causing the switch has disappeared. | 
 | 
| "Revertive" | 
 | 
| 
 | "OFF" | 
Table 2-1  – Configuration parameters (1/6)
Installation and User Guide - N56717020101
| Page  | No reproduction or communication without the written consent of SAGEM SA | 