1

 

 

 

 

 

 

 

 

 

 

 

 

1. Specifications

1-2 Major Component Specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(A) Indoor Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODEL No.

 

 

 

 

 

KH2442

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Source

 

 

 

 

230 - 208 V / 1 phase / 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote controller (Option)

 

 

 

 

 

RCS - BH80UA, WL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Controller P. C. B Ass'y

 

 

 

 

 

CR - TH2442

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Control circuit fuse

 

 

 

 

 

250 V, 3 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan

 

 

 

 

 

Cross-flow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number ... Dia. and length

in.

(mm)

 

1 ... O.D. 4-1/3 (110), L39 (990)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

 

 

 

 

 

UF4Q - 31A6P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Source

 

 

 

 

230 - 208 V / 1 phase / 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No. of pole … r.p.m. (230 V, High)

 

rpm

 

 

 

4 ... 1,276

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal output

 

W

 

 

 

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coil resistance

 

Ω

BRW -

WHT

:

197.2

,

ORG -

YEL

:

59.1

 

 

 

(Ambient temperature 68 °F)

 

 

WHT -

VLT

:

41.4

,

YEL

-

PNK

:

48.8

 

 

 

 

 

 

VLT -

ORG

:

22.2

,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Safety device

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating temperature

Open

°F

 

 

 

248

±

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Close

°F

 

 

 

171

±

27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Run capacitor

VAC,

μF

 

 

 

440 V , 1.8 μF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electronic refrigerant control valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Solenoid control model

 

 

 

 

 

DKV - MOZS582E0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coil resistance

 

Ω

ORG -

GRY

:

46

,

YEL

-

GRY

:

46

 

 

 

(Ambient temperature 68 °F)

 

 

RED -

GRY

:

46

,

BLK

-

GRY

:

46

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Solenoid control valve model

 

 

 

 

 

IKV - 24D11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat exchanger

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coil

 

 

 

Aluminum plate fin / Copper tube

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rows …

 

 

 

 

 

3 … 12.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Face area

ft.2

(m2)

 

 

 

2.57 (0.24)

 

 

 

 

 

 

Louver Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

 

 

 

 

 

M2EA24ZA01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rating

 

 

 

 

 

208 to 230 V, 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No. of pole … rpm

 

 

 

 

 

 

8 … 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

 

W

 

 

 

 

2.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coil resistance (Ambient temperature 68 °F)

 

kΩ

 

 

 

16.45 ± 8 %

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE

SM830082

I - 20

Page 24
Image 24