1. Specifications

 

1-7 Cooling Capacity

 

 

 

 

 

 

 

 

 

 

 

Indoor Unit: XH2442

Outdoor Unit: CH2442

 

 

 

 

 

 

 

 

 

• 230V / 1 phase / 60Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATING CAPACITY :

24,000 BTU/h

AIR FLOW RATE:

 

540 CFM

 

 

EVAPORATOR

 

 

 

 

CONDENSER

 

 

 

 

 

 

 

 

 

ENT.TEMP.°F(°C)

 

 

 

 

AMBIENT TEMP °F(°C)

 

 

 

 

 

 

WB

DB

 

 

 

75

85

95

105

 

115

 

 

 

 

 

 

 

(23.9)

(29.4)

(35.0)

(40.6)

 

(46.1)

 

 

 

 

 

TC

 

24,310

23,140

21,790

20,280

 

18,600

 

 

 

 

 

CI

 

1.71

1.86

 

2.03

2.26

 

 

2.49

 

 

 

72(22.2)

 

SHC

 

16,680

16,020

15,280

14,470

 

13,600

 

 

59

76(24.4)

 

SHC

 

18,480

17,820

17,080

16,270

 

15,400

 

 

(15.0)

80(26.7)

 

SHC

 

20,360

19,700

18,960

18,150

 

17,280

 

 

 

84(28.9)

 

SHC

 

22,160

21,500

20,760

19,950

 

18,600

 

 

 

88(31.1)

 

SHC

 

23,960

23,140

21,790

20,280

 

18,600

 

 

 

 

 

TC

 

25,220

24,100

22,900

21,530

 

20,040

 

 

 

 

 

CI

 

1.72

1.89

 

2.06

2.29

 

 

2.52

 

 

 

72(22.2)

 

SHC

 

14,330

13,750

13,140

12,460

 

11,750

 

 

63

76(24.4)

 

SHC

 

16,130

15,550

14,940

14,260

 

13,550

 

 

(17.2)

80(26.7)

 

SHC

 

18,010

17,430

16,820

16,140

 

15,430

 

 

 

84(28.9)

 

SHC

 

19,810

19,230

18,620

17,940

 

17,230

 

 

 

88(31.1)

 

SHC

 

21,610

21,030

20,420

19,740

 

19,030

 

 

 

 

 

TC

 

26,180

25,150

#

24,000

22,730

 

21,340

 

 

 

 

 

CI

 

1.74

1.9

2.08

2.32

 

2.55

 

 

 

72(22.2)

 

SHC

 

11,960

11,470

 

10,940

10,360

 

 

9,750

 

 

67

76(24.4)

 

SHC

 

13,760

13,270

12,740

12,160

 

11,550

 

 

(19.4)

80(26.7)

 

SHC

 

15,640

15,150

14,620

14,040

 

13,430

 

 

 

84(28.9)

 

SHC

 

17,440

16,950

16,420

15,840

 

15,230

 

 

 

88(31.1)

 

SHC

 

19,240

18,750

18,220

17,640

 

17,030

 

 

 

 

 

TC

 

27,580

26,620

25,580

24,460

 

23,210

 

 

 

 

 

CI

 

1.76

1.92

2.11

2.35

 

2.59

 

 

 

72(22.2)

 

SHC

 

9,650

9,230

 

8,790

8,330

 

 

7,820

 

 

71

76(24.4)

 

SHC

 

11,450

11,030

10,590

10,130

 

9,620

 

 

(21.7)

80(26.7)

 

SHC

 

13,330

12,910

12,470

12,010

 

11,500

 

 

 

84(28.9)

 

SHC

 

15,130

14,710

14,270

13,810

 

13,300

 

 

 

88(31.1)

 

SHC

 

16,930

16,510

16,070

15,610

 

15,100

 

 

 

 

 

TC

 

28,130

27,220

26,260

25,150

 

23,980

 

 

 

 

 

CI

 

1.79

1.96

2.14

2.38

 

2.63

 

 

75

76(24.4)

 

SHC

 

8,850

8,500

8,130

7,720

 

7,290

 

 

(23.9)

80(26.7)

 

SHC

 

10,730

10,380

10,010

9,600

 

9,170

 

 

 

84(28.9)

 

SHC

 

12,530

12,180

11,810

11,400

 

10,970

 

 

 

88(31.1)

 

SHC

 

14,330

13,980

13,610

13,200

 

12,770

 

 

 

TC :Total Cooling Capacity

(BTU/h)

 

 

 

 

 

 

 

 

 

 

 

SHC:Sensible Heat Capacity

(BTU/h)

 

 

 

 

 

 

 

 

 

 

 

CI :Compressor Input (kW)

 

 

 

 

 

 

 

 

 

 

 

Rating conditions are

 

 

 

 

 

 

 

 

 

 

 

 

 

 

:Outdoor Ambient Temp.95° FDB

 

 

 

 

 

 

 

 

 

 

 

:Indoor Unit Entering Air Temp.80° FDB/67° FWB

 

 

 

 

 

 

 

 

1

SM830082

I - 51

Page 55
Image 55
Sanyo UH2442 / CH2442, XH3642 / CH3642 Cooling Capacity Indoor Unit XH2442 Outdoor Unit CH2442, 230V / 1 phase / 60Hz