1

1. Specifications

Indoor Unit: UH2442

Outdoor Unit: CH2442

 

 

 

 

 

 

 

• 208V / 1 phase / 60Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATING CAPACITY :

23,400 BTU/h

 

AIR FLOW RATE:

 

600 CFM

 

EVAPORATOR

 

 

 

 

 

CONDENSER

 

 

 

 

 

 

 

 

ENT.TEMP.°F(°C)

 

 

 

 

 

AMBIENT TEMP °F(°C)

 

 

 

 

 

WB

DB

 

 

 

75

85

95

105

 

115

 

 

 

 

 

 

 

(23.9)

(29.4)

(35.0)

(40.6)

 

(46.1)

 

 

 

 

 

TC

 

23,700

22,560

21,250

19,770

 

18,140

 

 

 

 

 

CI

 

1.75

 

1.92

 

2.09

2.33

 

2.56

 

 

 

72(22.2)

 

SHC

 

16,860

16,260

15,590

14,850

 

14,050

 

 

59

76(24.4)

 

SHC

 

18,930

18,330

17,660

16,910

 

16,120

 

 

(15.0)

80(26.7)

 

SHC

 

21,090

20,490

19,820

19,070

 

18,140

 

 

 

84(28.9)

 

SHC

 

23,150

22,560

21,250

19,770

 

18,140

 

 

 

88(31.1)

 

SHC

 

23,700

22,560

21,250

19,770

 

18,140

 

 

 

 

 

TC

 

24,590

23,490

22,320

20,990

 

19,540

 

 

 

 

 

CI

 

1.77

 

1.94

 

2.12

2.36

 

2.6

 

 

 

72(22.2)

 

SHC

 

14,280

13,750

13,190

12,580

 

11,920

 

 

63

76(24.4)

 

SHC

 

16,340

15,810

15,260

14,640

 

13,990

 

 

(17.2)

80(26.7)

 

SHC

 

18,500

17,970

17,420

16,800

 

16,150

 

 

 

84(28.9)

 

SHC

 

20,570

20,040

19,490

18,870

 

18,210

 

 

 

88(31.1)

 

SHC

 

22,630

22,100

21,550

20,940

 

19,540

 

 

 

 

 

TC

 

25,530

24,520

#

23,400

22,160

 

20,800

 

 

 

 

 

CI

 

1.79

1.96

2.14

2.39

 

2.63

 

 

 

72(22.2)

 

SHC

 

11,680

 

11,230

 

10,750

10,220

 

9,660

 

 

67

76(24.4)

 

SHC

 

13,740

13,300

12,810

12,290

 

11,720

 

 

(19.4)

80(26.7)

 

SHC

 

15,900

15,460

14,970

14,450

 

13,880

 

 

 

84(28.9)

 

SHC

 

17,970

17,530

17,040

16,510

 

15,950

 

 

 

88(31.1)

 

SHC

 

20,040

19,590

19,110

18,580

 

18,010

 

 

 

 

 

TC

 

26,890

25,950

24,940

23,840

 

22,630

 

 

 

 

 

CI

 

1.81

1.98

2.17

2.42

 

2.67

 

 

 

72(22.2)

 

SHC

 

9,110

 

8,730

 

8,330

7,900

 

7,440

 

 

71

76(24.4)

 

SHC

 

11,170

10,800

10,400

9,970

 

9,500

 

 

(21.7)

80(26.7)

 

SHC

 

13,330

12,960

12,560

12,130

 

11,660

 

 

 

84(28.9)

 

SHC

 

15,400

15,020

14,620

14,190

 

13,730

 

 

 

88(31.1)

 

SHC

 

17,460

17,090

16,690

16,260

 

15,800

 

 

 

 

 

TC

 

27,420

26,540

25,600

24,520

 

23,380

 

 

 

 

 

CI

 

1.84

 

2.01

 

2.2

2.46

 

2.71

 

 

75

76(24.4)

 

SHC

 

8,360

8,050

7,710

7,330

 

6,940

 

 

(23.9)

80(26.7)

 

SHC

 

10,520

10,210

9,870

9,490

 

9,100

 

 

 

84(28.9)

 

SHC

 

12,590

12,270

11,940

11,560

 

11,170

 

 

 

88(31.1)

 

SHC

 

14,660

14,340

14,000

13,630

 

13,230

 

 

 

TC :Total Cooling Capacity

(BTU/h)

 

 

 

 

 

 

 

 

 

 

 

SHC:Sensible Heat Capacity

(BTU/h)

 

 

 

 

 

 

 

 

 

 

 

CI :Compressor Input (kW)

 

 

 

 

 

 

 

 

 

 

 

Rating conditions are

 

 

 

 

 

 

 

 

 

 

 

 

 

 

:Outdoor Ambient Temp.95° FDB

 

 

 

 

 

 

 

 

 

 

 

:Indoor Unit Entering Air Temp.80° FDB/67° FWB

 

 

 

 

 

 

 

SM830082

I - 64

Page 68
Image 68
Sanyo KH3642 / CH3642, XH3642 / CH3642, XH4242 / CH4242, XH2442 / CH2442, UH3642 / CH3642, TH4242 / CH4242 Indoor Unit UH2442