1. Specifications

1-9 Performance Charts

Cooling Characteristics

(1) Operating Current

1 Indoor Unit: XH4242

Outdoor Unit: CH4242

Operating current characteristics versus outdoor ambient temperature and indoor temperature. (Indoor relative humidity: 50%, Indoor fan speed: High)

230V

 

24

 

 

 

 

23

 

(A)

22

 

current

21

 

 

 

Operating

20

 

18

 

 

19

 

 

17

 

 

 

 

 

59

 

(15)

Outdoor fan speed

Indoor

Low

 

 

 

High

temp.

 

 

 

 

 

 

 

°F (°C)

85 (30)

80 (27)

75 (24)

70 (21)

68

77

86

95

104

(20)

(25)

(30)

(35)

(40)

Outdoor ambient temp. °F (°C)

2223_X_S

208V

 

24

 

 

 

 

23

 

(A)

22

 

current

21

 

 

 

Operating

20

 

18

 

 

19

 

 

17

 

 

 

 

 

59

 

(15)

Outdoor fan speed

Indoor

Low

High

temp.

 

 

°F (°C)

85 (30)

80 (27)

75 (24)

70 (21)

68

77

86

95

104

(20)

(25)

(30)

(35)

(40)

Outdoor ambient temp. °F (°C)

2224_X_S

1

SM830082

I - 73