Sanyo UH2442 / CH2442, XH3642 / CH3642 Service procedures Symptoms and parts to inspect

Models: TH4242 / CH4242 XH2442 / CH2442 XH3642 / CH3642 KH2442 / CH2442 UH3642 / CH3642 TH2442 / CH2442 UH2442 / CH2442 TH3642 / CH3642 KH3642 / CH3642 XH4242 / CH4242

1 202
Download 202 pages 41.27 Kb
Page 165
Image 165

4. Service procedures

(5)Symptoms and parts to inspect

1)Symptom: LCD on the remote controller does not display and remote controller does not

operate.

Miswiring of

Yes

Is there 230-208 V AC

power supply

 

 

between U1 and U2

 

 

wires and

 

 

of the terminal plate?

indoor/outdoor

 

 

 

No

 

 

 

control lines

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Correct the

Check and repair the

wiring. Remove the

power breaker etc.

socket connected to

 

the OC plug on the

 

PCB and connect to

 

the EMG plug instead.

 

Start

 

 

 

Is the LED (D80) on

Yes

the indoor unit PCB lit?

 

 

 

 

 

No

 

 

 

 

 

 

 

No Is there 230-208 V AC between R and S of

the indoor PCB?

Yes

Repair the remote controller wiring.

Correct the

 

No

Are the connections

No

Has the indoor

 

 

 

 

 

 

connections

 

 

for the 4P connector

 

 

unit PCB fuse blown?

 

 

 

 

 

 

 

 

 

for the indoor unit’s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

PCB power trans-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

former good?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

No

 

Replace the

No

Is there 15 V AC

 

 

Is the primary

 

Is the 230-208 V AC

Replace the

indoor unit power

 

between 1 and 2

 

 

side of the indoor

 

 

circuit shorted?

 

indoor unit PCB.

 

 

 

 

transformer.

 

of the 4P connector

 

 

power transformer

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

for the indoor unit’s

 

 

shorted?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

power transformer?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace the

 

Replace the indoor unit’s

 

Replace or repair.

 

 

 

 

 

indoor unit PCB.

 

power transformer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2095_THS_I

SM830082

4

IV - 9

Page 165
Image 165
Sanyo UH2442 / CH2442, XH3642 / CH3642, XH4242 / CH4242, XH2442 / CH2442 Service procedures Symptoms and parts to inspect