SELECTING THE INSTALLATION SITE

Indoor Unit

AVOID:

 

areas where leakage of flammable gas may be

 

expected.

 

places where large amounts of oil mist exist.

 

direct sunlight.

 

locations near inverter lamps which may affect

 

performance of the unit.

 

locations near heat sources which may affect

 

performance of the unit.

 

locations where external air may enter the room

 

directly. This may cause “sweating” on the air

 

discharge ports, causing them to spray or drip.

1

locations where the remote control unit will be

splashed with water or affected by dampness or

 

humidity.

 

installing the remote control unit behind curtains or

 

furniture.

 

locations where the receiver in the indoor unit is

 

exposed to the inverter lamp light. Faulty operation

 

of the unit occurs.

DO:

select an appropriate position from which every corner of the room can be uniformly cooled.

select a location where the ceiling is strong enough to support the weight of the unit.

select a location where tubing and drain pipe have the shortest run to the outdoor unit.

allow room for operation and maintenance as well as unrestricted air flow around the unit.

install the unit within the maximum elevation difference above or below the outdoor unit and within a total tubing length from the outdoor unit as detailed in Table 1-10.

allow room for mounting the remote control unit about 3 ft. off the floor, in an area that is not in direct sunlight nor in the flow of cool air from the indoor unit.

NOTE

Air delivery will be degraded if the distance from the floor to the ceiling is greater than 10 ft..

1. Specifications

Ceiling-Mounted Type

 

Ceiling

 

Wall

Min.10 inch

Min.10 inch

Front view

NOTE

The rear of the indoor unit can be installed flush against the wall.

AirCeiling discharge

 

 

 

Air intake

Min.2 ft.

 

 

 

 

 

 

 

Side view

1091_T_I

4-Way Air Discharge Type

Concealed-Duct Type

3 ft.

 

3 ft.

 

3 ft.

3 ft.

3 ft.

 

1960_X_I

Wall-Mounted Type

 

Min.

 

6 inch

Min.

Min.

6 inch

12 inch

 

0930_K_I