Sanyo KH2442 / CH2442 Checking the Electrical Components, Measurement of Insulation, Resistance

Models: TH4242 / CH4242 XH2442 / CH2442 XH3642 / CH3642 KH2442 / CH2442 UH3642 / CH3642 TH2442 / CH2442 UH2442 / CH2442 TH3642 / CH3642 KH3642 / CH3642 XH4242 / CH4242

1 202
Download 202 pages 41.27 Kb
Page 186
Image 186

 

 

 

4. Service procedures

4-2

Checking the Electrical Components

Earthed wire

 

(1)

Measurement of Insulation

 

Clip

 

 

 

 

 

Resistance

 

 

 

• The electrical insulation is acceptable when the

Probe

 

 

resistance exceeds 1 MΩ.

 

Insulation

 

 

 

 

Fig. IV-14

 

 

 

tester

0638_X_S

1Power Supply Wires

Clamp the earthed wire of the Power Supply wires with a lead clip of the insulation resistance tester and measure the resistance by placing a probe on either of the power wires. (Fig. IV-14)

Then measure the resistance between the earthed wire and the other power wires. (Fig. IV-14)

2Indoor Unit

Clamp an aluminum plate fin or copper tube with the lead clip of the insulation resistance tester and measure the resistance by placing a probe on the terminal plate (Fig. IV-15)

Terminal plate

Probe

Clip

4

3Outdoor Unit

Measure the resistance by placing a probe on the terminal plate in the same manner as explained above 2. (Fig. IV-15)

4Measurement of Insulation Resistance for Electrical parts

Disconnect the connector of the desired electric part from terminal plate, P.C.B. Ass’y, etc. (Fig. IV-16)

Similarly, disconnect the lead wires from compressor, capacitor, etc. (Fig. IV-17)

Measure the resistance in the same manner as illustrated on the right.

Refer to Electrical Wiring Diagram.

NOTE

If the probe does not enter the hole because the hole is too narrow, use a probe with a thinner pin.

Copper

Insulation

tube or

tester

metallic part

 

0639_X_S

Probe

Clip

Copper tube or metallic part

Insulation tester

0640_X_S

From fan motor, compressor and other parts.

Metallic

Probe

part

 

Clip

 

Insulation tester

0641_X_S

Fig. IV-15

Fig. IV-16

Fig. IV-17

SM830082

IV - 30

Page 186
Image 186