4. Service procedures

(7)Service Functions of Optional Wired Remote Controller

From the remote controller you can control both the operation and settings of the unit as well as perform several useful service checks. This section explains how to use the remote controller on the following items from (A) to (I).

(A)Use the test run procedure.

(B)Check the sensor temperature readings.

(C)Accessing the service problem history.

(D)Check the remote controller itself for correct operation.

(E)Excute the auto. address operation.

(F)Confirm and change the indoor unit address.

(G)Change the shift temperature in heating mode

(H)Set the indoor unit address.

( I ) Change the period of the filter timer

(A)Use the test run procedure

aAfter holding down the remote controller button for 4 seconds or more, press the

button.

While the test is running, “TEST” shows on the LCD display.

In “TEST” mode, the temperature cannot be adjusted. Do not use this mode except during test run operation.

bUse “TEST” mode in either heating or cooling operation mode.

NOTE

The outdoor unit will not start running for approximately 3 minutes after the power is turned on or the unit is turned off.

c When the unit is not operating normally, a code will be displayed on the remote controller LCD. Refer to the Table of Self-Diagnostic Functions at “- - -”, and take the corrective measures indicated.

dAfter completing the test run operation,

press the

button again and check to

a

see that “TEST” is no longer displayed on

the remote controller LCD.

 

(The remote controller is equipped with a

 

timer that terminates test run operation

 

after 60 minutes in order to prevent con-

 

tinuous test run operation.)

 

 

a, d

2076_M_I

 

 

Fig. IV-3

4

SM830082

IV - 21

Page 177
Image 177
Sanyo TH3642 / CH3642, XH3642 / CH3642, XH4242 / CH4242, XH2442 / CH2442, UH3642 / CH3642 Use the test run procedure