63230-500-225A2

PowerLogicTM Series 800 Power Meter

3/2011

 

 

Chapter 7—Logging

 

Table 7–4: Values Stored in the Maintenance Log

 

 

 

 

 

Record

Value Stored

 

 

Number

 

 

 

 

 

1

Time stamp of the last change

 

 

 

 

 

2

Date and time of the last power failure

 

 

 

 

3

Date and time of the last firmware download

 

 

 

 

4

Date and time of the last option module change

 

 

 

 

5

Date and time of the latest LVC update due to configuration errors

detected during meter initialization

 

 

 

 

6–11

Reserved

 

 

 

 

12

Date and time the Present Month Min/Max was last reset

 

 

 

 

13

Date and time the Previous Month Min/Max was last reset

 

 

 

 

14

Date and time the Energy Pulse Output was overdriven

 

 

 

 

15

Date and time the Power Demand Min/Max was last reset

 

 

 

 

16

Date and time the Current Demand Min/Max was last reset

 

 

 

 

17

Date and time the Generic Demand Min/Max was last reset

 

 

 

 

18

Date and time the Input Demand Min/Max was last reset

 

 

 

 

19

Reserved

 

 

 

 

20

Date and time the Accumulated Energy value was last reset

 

 

 

 

21

Date and time the Conditional Energy value was last reset

 

 

 

 

22

Date and time the Incremental Energy value was last reset

 

 

 

 

23

Reserved

 

 

 

 

24

Date and time of the last Standard KY Output operation

 

 

 

 

25

Date and time of the last Discrete Output @A01 operation

 

 

 

 

26

Date and time of the last Discrete Output @A02 operation

 

 

 

 

27

Date and time of the last Discrete Output @A03 operation

 

 

 

 

28

Date and time of the last Discrete Output @A04 operation

 

 

 

 

29

Date and time of the last Discrete Output @A05 operation

 

 

 

 

30

Date and time of the last Discrete Output @A06 operation

 

 

 

 

31

Date and time of the last Discrete Output @A07 operation

 

 

 

 

32

Date and time of the last Discrete Output @A08 operation

 

 

 

 

33

Date and time of the last Discrete Output @B01 operation

 

 

 

 

34

Date and time of the last Discrete Output @B02 operation

 

 

 

 

35

Date and time of the last Discrete Output @B03 operation

 

 

 

 

36

Date and time of the last Discrete Output @B04 operation

 

 

 

 

37

Date and time of the last Discrete Output @B05 operation

 

 

 

 

38

Date and time of the last Discrete Output @B06 operation

 

 

 

 

39

Date and time of the last Discrete Output @B07 operation

40Date and time of the last Discrete Output @B08 operation

Additional outputs require option modules and are based on the I/O configuration of that particular module.

© 2011 Schneider Electric. All Rights Reserved.

59

Page 65
Image 65
Schneider Electric PM820, PM870, PM810, PM850 manual Value Stored, Number