Configuring the conference system via the central unit

Remedy

￿Perform a manual self-test (see page 40). The display can change as follows:

The structural change icon K disappears: The structural change has been detected, there are no errors.

The structural change icon K is still displayed: Follow the steps below.

If, after performing the self-test, the structural change icon K is still displayed:

￿Reset the error counter (“Break Counter”) (see page 40).

￿Change to the “Bus Statistics” menu item (see page 39) and check the digit behind “Break Counter”.

￿Carefully move the conference units and systems cables and check if the digit behind “Break Counter” is increased.

If the digit is increased, check the corresponding plug connec- tions or replace the corresponding conference units and system cables.

If the error still occurs:

￿Follow the steps described in the “System Load” menu item (see page 38).

￿Perform a manual self-test (see page 40).

Display

Direct Access

30 Units

20The warning triangle N and the

structural change icon K are displayed.

 

N

K

Error and Change in the number of conference units during the self-test:

remedy

After switch-on, an automatic self-test is performed which simu-

 

 

lates a running conference with all the conference units connected.

 

If a failure of conference units occurs, the above mentioned error

 

icons appear.

 

 

A failure of conference units can be caused by undervoltages or

 

overcurrents:

 

 

￿ Follow the steps described in the “System Load” menu item

 

(see page 38).

 

 

￿ Perform a manual self-test (see page 40).