Configuring the conference system via the central unit

System analysis – “Diagnostics” submenu

Main Menu

System

Diagnostics

Conference

Ports

System Load

Audio

Diagnostics

Temperature

System

Versions

Bus Statistics

 

No

No

Select and call up the “System” submenu

Select and call up the

The “Diagnostics”

“Diagnostics” submenu

submenu appears

Displaying status information on the current and voltage supply – “System Load”

The “Diagnostics” menu item provides information on the status of the current and voltage supply, on the status of data transmission and on interruptions due to faulty cables or cable connections.

 

Diagnostics

Load

 

 

Main Menu

System Load

 

Current

Voltage

System

Temperature

Port 1

 

Diagnostics

Bus Statistics

Port 2

 

– –

 

 

No

 

 

No

Select and call up the

Select and call up the

 

View the information;

“Diagnostics” submenu

“Load” menu item

 

exit the menu item

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Both ports can be subjected to undervoltages, overcurrents and short-circuits:

Display

Meaning and causes

Current

An overcurrent in the central unit can be caused by

 

• metal parts (e.g. paper clips) that bridge the contacts of the plug

 

 

connections

 

faulty conference units

 

faulty system cables

 

• too long system cables

 

• too many conference units connected to one port

 

 

Voltage

An undervoltage can be caused by

 

faulty conference units

 

• too long system cables

 

• too many conference units connected to one port

 

 

Current

A short-circuit in the central unit can be caused by e.g.

 

• metal parts (e.g. paper clips) that bridge the contacts of the plug

 

 

connections

 

faulty system cables

 

• wrong cables (e.g. crossover cables)

Voltage

The port is deactivated due to e.g.

--• no conference units connected

• a short-circuit

If an error icon appears (see page 34), check your conference system for the errors mentioned above.

If an error is detected at startup of the central unit, first eliminate the error and then perform a manual self-test(see page 40) in order to check if the error still occurs.

If an error has only occured during operation and has already been elim- inated, this is automatically detected by the central unit.

Possible steps for error elimination:

Eliminate the errors separately for each port.

Calculate the maximum length of the cable string (see page 13) and, if neces- sary, reduce the cable length.

Reduce the number of conference units to 15-20 max. per cable string.