Configuring the conference system via the central unit
System analysis – “Diagnostics” submenu
Main Menu | System | Diagnostics |
Conference | Ports | System Load |
Audio | Diagnostics | Temperature |
System | Versions | Bus Statistics |
| No | No |
Select and call up the “System” submenu
Select and call up the | The “Diagnostics” |
“Diagnostics” submenu | submenu appears |
Displaying status information on the current and voltage supply – “System Load”
The “Diagnostics” menu item provides information on the status of the current and voltage supply, on the status of data transmission and on interruptions due to faulty cables or cable connections.
| Diagnostics | Load |
|
|
Main Menu | System Load |
| Current | Voltage |
System | Temperature | Port 1 | ☺ |
|
Diagnostics | Bus Statistics | Port 2 |
| – – |
|
| No |
|
| No |
Select and call up the | Select and call up the |
| View the information; | ||
“Diagnostics” submenu | “Load” menu item |
| exit the menu item | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Both ports can be subjected to undervoltages, overcurrents and
Display | Meaning and causes | |
Current | An overcurrent in the central unit can be caused by | |
| • metal parts (e.g. paper clips) that bridge the contacts of the plug | |
|
| connections |
| • | faulty conference units |
| • | faulty system cables |
| • too long system cables | |
| • too many conference units connected to one port | |
|
| |
Voltage | An undervoltage can be caused by | |
| • | faulty conference units |
| • too long system cables | |
| • too many conference units connected to one port | |
|
| |
Current | A | |
| • metal parts (e.g. paper clips) that bridge the contacts of the plug | |
|
| connections |
| • | faulty system cables |
| • wrong cables (e.g. crossover cables) | |
Voltage | The port is deactivated due to e.g. |
--• no conference units connected
• a
If an error icon appears (see page 34), check your conference system for the errors mentioned above.
If an error is detected at startup of the central unit, first eliminate the error and then perform a manual
If an error has only occured during operation and has already been elim- inated, this is automatically detected by the central unit.
Possible steps for error elimination:
•Eliminate the errors separately for each port.
•Calculate the maximum length of the cable string (see page 13) and, if neces- sary, reduce the cable length.
•Reduce the number of conference units to