Configuring the conference system via the central unit
Performing a manual
Permanent transmission errors must be eliminated immediately in order to ensure
You can manually reset the “ ” icon behind “Error Indication” to the default icon (“☺”) (see page 40).
The error counter (“Break Counter”) incrementally counts all errors and changes in the conference system (e.g. added conference units). Based on the changes of the counter’s counts, you can conclude on the error source (e.g. if the counter rapidly increments when you wiggle the cable, this indicates a faulty cable).
You can manually reset the error counter (“Break Counter”) (see page 40).
| Diagnostics | Start |
Main Menu | Temperature | Yes |
System | Bus Statistics | No |
Diagnostics | Start | Start |
|
| No |
|
| No |
Select and call up the | Select and call up |
| Select the desired | ||
the “Start |
| setting; apply the | |||
“Diagnostics” submenu |
| ||||
menu item |
| setting | |||
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Resetting the error counter – “Reset Break Indication”
If the central unit detects errors after
Eliminate these errors (see page 34 and following).
Perform a manual
The central unit now checks if a reported error still occurs. If the error is elimi- nated, the corresponding error icon goes off after the
Always perform the
Main Menu |
|
|
|
|
|
| Diagnostics |
|
| Reset Break Indication | |||||
|
|
|
|
| Bus Statistics |
|
|
| Yes |
| |||||
|
|
|
|
|
|
| |||||||||
System |
|
|
| Start Self Test |
|
| No |
| |||||||
| Diagnostics |
|
|
| Reset Break Indication |
|
|
|
|
|
| ||||
Select and call up the |
| Select and call up the |
| Select the desired | |||||||||||
| “Reset Break Indication” |
| |||||||||||||
“Diagnostics” submenu |
|
| setting; apply the setting | ||||||||||||
| menu item |
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Resetting the display of data bus errors – “Reset Error Indication”
Possible settings: “Yes” or “No”
This menu item allows you to reset the error counter (“Break Count”) in the “Bus Statistic” menu item (see page 39).
Main Menu |
|
|
|
|
|
| Diagnostics |
|
| Reset Error Indication | ||||
|
|
|
|
| Start Self Test |
|
|
| Yes | |||||
|
|
|
|
|
| |||||||||
System |
|
|
| Reset Break indication |
|
| No | |||||||
| Diagnostics |
|
|
| Reset Error Indication |
|
|
|
|
| ||||
Select and call up the |
|
| Select and call up |
|
| Select the desired | ||||||||
|
| the “Reset Error |
|
| setting; apply the | |||||||||
“Diagnostics” submenu |
|
|
|
| ||||||||||
|
| Indication” menu item |
|
| setting | |||||||||
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Possible settings: “Yes” or “No”
This menu item allows you to manually reset the display of data bus errors (“Error Indication”) in the “Bus Statistic” menu item to default (see page 39).
40