Appendix
-113

AC socket

POWER button

Adjustment buttons

("|"|
"|"|
"|)
ENTER button

User service screw

4Loosen the lamp unit.
Remove the securing screws from the
lamp unit. Hold the lamp unit by the
handle and pull it in the direction of
the arrow.
5Insert the new lamp unit.
Press the lamp unit firmly into the lamp
unit compartment. Fasten the secur-
ing screws.
6Attach the lamp unit cover.
Slide the lamp unit cover in the direc-
tion of the arrow. Then tighten the user
service screw.
Info
If the lamp unit and lamp cover are not
correctly installed, the power will not turn
on, even if the power cord is connected
to the projector.

Resetting the Lamp

Timer

Reset the lamp timer after replacing the lamp.
1Connect the power cord.
Plug the power cord into the AC socket
of the projector.
2 Reset the lamp timer.
While pressing simultaneously
, , and on the projec-
tor, press on the projector.
LAMP 0000H is displayed, indicating
that the lamp timer is reset.
Info
Make sure to reset the lamp timer only
when replacing the lamp. If you reset the
lamp timer and continue to use the same
lamp, this may cause the lamp to become
damaged or explode.

Securing

screw

PG-M25X#E#p107_115.p65 02.4.29, 3:26 PM113