4 Loosen the lamp unit.

Remove the securing screws from the lamp unit. Hold the lamp unit by the handle and pull it in the direction of the arrow.

5 Insert the new lamp unit.

Press the lamp unit firmly into the lamp unit compartment. Fasten the secur- ing screws.

6 Attach the lamp unit cover.

Slide the lamp unit cover in the direc- tion of the arrow. Then tighten the user service screw.

Info

If the lamp unit and lamp cover are not correctly installed, the power will not turn on, even if the power cord is connected to the projector.

Resetting the Lamp

Timer

Reset the lamp timer after replacing the lamp.

1 Connect the power cord.

Plug the power cord into the AC socket of the projector.

2 Reset the lamp timer.

While pressing simultaneously

, , and on the projec-

tor, press on the projector.

“LAMP 0000H” is displayed, indicating that the lamp timer is reset.

Info

Make sure to reset the lamp timer only when replacing the lamp. If you reset the lamp timer and continue to use the same lamp, this may cause the lamp to become damaged or explode.