Cleaning the Machine

8. Maintenance

Cleaning the Machine

Cleaning the scanning glass and rollers

Any dirt on the scanning glass and rollers will degrade the quality of transmitted documents and copies. Clean these frequently as explained below.

1Open the operation panel.

2Rotate the lever on the left side of the roller forward so that it points straight up.

3Pull the left side of the white roller up out of its holder.

4Wipe the scanning glass and rollers with a clean cloth or swab.

Make sure that all dirt and stains (such as correcting fluid) are removed. Dirt and stains will cause vertical lines on transmitted images and copies.

If the scanning glass is difficult to clean, try moistening the cloth with isopropyl alcohol or denatured alcohol. Take care that no alcohol gets on the rollers.