Monitoring Module Status

You can monitor the module status using the yellow, green and orange LED status indicators on the Evaluation Daughtercard. Table 2 defines the default functions of the LED status indicators.

 

 

Table 2 Status Monitors

 

 

 

 

Function

State

 

Status

 

 

 

 

 

On

 

The module is receiving power

Power

 

 

 

Off

 

The module is not receiving power

 

 

Orange (D8)

 

 

 

Blinking

 

Firmware update is in progress (Important: Do not

 

 

 

 

power off the module during the update process)

 

 

 

 

 

 

 

Network Status

Yellow On

 

Wireless connection established

Yellow (D9)

 

 

 

 

 

 

 

 

OEM Interface

The OEM interface is a 40-pin header (JP2) that is used to connect the SX-560 module to the SX-560-6900 Evaluation Daughtercard. It will also serve as the primary means of communications between the SX-560 and your OEM device (refer to Chapter 5 for information on using this header to connect with your device).

Table 3 shows the OEM interface pinout for the Evaluation Daughtercard. Table 4 shows the OEM interface signal descriptions. Please note that the OEM interface signals are not directly accessible from the OEM header when the Evaluation Daughtercard is used. Rather, these signals are available through convenient connectors on the Evaluation Daughtercard, such as the 26-pin I/O Header and the 9-pin serial connectors. These connectors are described later in this chapter.

All input and output signals, except the differential signals, are 0 to 3.3 V logic signals.

Table 3 OEM Interface Pinout

 

PIN

SIGNAL

PIN

SIGNAL

 

 

1

RESETI-

2

GPIO_0

 

 

3

GPIO_1

4

GPIO_2

 

 

5

GROUND

6

+3.3VDC

 

 

7

GPIO_3

8

GPIO_4

 

 

9

GPIO_5

10

GPIO_6

 

 

11

GPIO_7

12

GPIO_8

 

 

13

GPIO_9

14

TXD0

 

 

15

GPIO_10

16

CTS0-

 

 

17

GROUND

18

+3.3VDC

 

 

19

USB+

20

RTS0-

 

 

21

USB-

22

RXD0

 

 

23

+3.3VDC

24

GROUND

 

 

25

SPI_CS-

26

TXD1

 

 

27

SPI_CLK

28

CTS1-

 

 

29

GROUND

30

+3.3VDC

 

 

31

SPI_MOSI

32

RTS1-

 

 

33

SPI_MISO

34

RXD1

 

 

35

+3.3VDC

36

GROUND

 

 

37

IIC_SDC

38

TXD2

 

 

39

IIC_SDA

40

RXD2

 

 

 

 

 

 

 

Installing the Evaluation Daughtercard

Silex

Part Number 140-00192-100

Page 9

Page 15
Image 15
Silex technology SX-560 manual Monitoring Module Status, OEM Interface, Status Monitors, Function State Status