LCD Interface

A 16x2 LCD display is available as an option for the SX-560-6900 Evaluation Daughtercard. This LCD can be controlled from either Serial Port 2 or via the SPI interface. The LCD display plugs into header JP1. Header JP12 is used to select serial or SPI control (place a jumper on pins 1 and 2 to select serial, or place the jumper on pins 2 and 3 to select SPI).

OEM Interface Electrical Characteristics

Table 12 OEM Signal Parameter Descriptions

Parameter

Symbol

Condition

Minimum

Maximum

Unit

 

 

 

 

 

 

Input high voltage

Vih

 

2.0!

 

Volts

 

 

 

 

 

 

Input low voltage

Vil

 

 

0.8

Volts

 

 

 

 

 

 

Output high voltage

Voh

Ioh = 4mA

2.4

 

Volts

UART0_TXD, UART0_RTS,

 

 

 

 

 

UART1_TXD, UART1_RTS

 

 

 

 

 

UART2_TXD

 

 

 

 

 

Output low voltage

Vol

Iol = 8mA

 

0.4

Volts

UART0_TXD, UART0_RTS,

 

 

 

 

 

UART1_TXD, UART1_RTS

 

 

 

 

 

UART2_TXD

 

 

 

 

 

Output high voltage

Voh

Ioh = 8mA

2.4

 

Volts

GPIO 1 to 10, SPI, CS, SPI_SDO,

 

 

 

 

 

SPI_CLK, Reset_N

 

 

 

 

 

 

 

 

 

 

 

Output low voltage

Vol

Iol = 8mA

 

0.4

Volts

GPIO 1 to 10, SPI, CS, SPI_SDO,

 

 

 

 

 

SPI_CLK, Reset_N

 

 

 

 

 

 

 

 

 

 

 

Input Leakage Current

Ii

0 < Vin < 3.3v

-10

+10

A

 

 

 

 

 

 