Description

 

 

SET NW

Sets WPA PSK pass phrase or hex key.

WPAPSK

This value is only used if the authentication mode is WPA-PSK or WPA2-PSK. The

 

 

argument to this command is either a pass phrase of 8 to 63 characters or exactly

 

64 hex characters representing the 256 bit PSK value.

 

Format:

 

 

SET NW WPAPSK <key>

 

 

SH NW DISCONN

Displays the current value of the network disconnection timer

 

Sample output:

 

 

Disconnect Timer: 5

 

 

SET NW

Sets the period of the network link disconnection watchdog timer. In wireless

DISCONN*

infrastructure mode, this timer monitors the wireless link, and if the unit is not

 

connected to an AP for the time specified, the unit is reset.

 

SET NW DISCONN nn

 

 

N = 0

watchdog timer is disabled

 

1-255

watchdog timer period in minutes

 

The factory default value is 5 minutes.

 

This timer also controls a receive activity monitor when the wireless network link is

 

connected. If no packets are received during the time specified, and the link

 

remains up, the unit will reset at the end of the time period.

 

 

SET NW RESET*

This command stops, and then resets the wireless network interface. This will

 

effectively disassociate the unit from an access point if it is connected. If the unit is

 

in wireless infrastructure mode, the unit will then scan and attempt to reconnect to a

 

suitable access point, if one is available.

 

Format:

 

 

SET NW RESET

 

 

 

 

*Not implemented in early releases of SX-560 firmware.

Port Commands

Table 35 Port Commands

Note: Examples shown are for Serial Port (S1). To use the commands with Serial Port 2 (S2), substitute the port name S2 instead of S1 in the command

.

Command

Description

SH PORT

Shows port parameters

Sample output:

Port Q-Size Type Attributes

*S1

0

serial

115200 N 8 1 XON/XOFF

Page 78