Parameter

Description

Settings

Default Setting

 

 

 

 

Econn

ECable connection attempt time

1-255 seconds

30 seconds

 

 

 

 

Ecport

ECable destination TCP port number

Set by user

N/A

 

 

 

 

Eclport

ECable destination local IP port

Set by user

N/A

 

number (required for E-Cable UDP

 

 

 

mode only)

 

 

 

 

 

 

Ectmmsec

Cable connection time resolution

Enable, Disable

Disable

 

 

 

 

Ecudp

ECable UDP mode

Enable, Disable

Disable

 

 

 

 

Restoring Factory Default Settings

The factory default settings can be restored at any time. If you are using the SX-560 Evaluation Daughtercard, hold down the test button for more than five seconds. If you are not using the evaluation board, short GPIO7 on the OEM header to ground (4.7 K-ohm pull-up resistor connected to +3.3VDC) for more than five seconds.

Modifying TCP/IP Settings

You can modify the TCP/IP settings using ExtendView, the web browser interface or the SX-560 module’s internal configuration console.

To modify TCP/IP settings:

1. Using ExtendView, click the TCP/IP tab. The TCP/IP window displays.

Figure 12 TCP/IP Window

Page 46

Silex

Part Number 140-00192-100

Advanced Configuration

Page 52
Image 52
Silex technology SX-560 manual Modifying TCP/IP Settings, Parameter Description Settings Default Setting