Table 23 GPIO Transmit Commands

Command

Description

 

 

SET GPIO TRANsmit <trigger #> <string>

Sets the string that will be included in an Email alert if

 

 

the trigger is activated. These strings are also used to

 

 

identify the trigger on the trap and alert web pages. This

 

 

value overrides the default string created when the

 

 

trigger is enabled, which is of the form “GPIO #<n> is

 

 

01>”.

 

 

<trigger #> is 1-16, and indicates the trigger condition

 

 

for which the string is being set. The remainder of the

 

 

line is taken as the string for the indicated trigger

 

 

number.

 

 

SHOW GPIO TRANsmit

Displays the string that will be included in an Email alert

SHOW GPIO TRANsmit <trigger #>

if the trigger is activated. These strings are also used to

identify the trigger on the trap and alert web pages.

 

 

 

 

There are two forms -- one displays all strings, the other

 

 

only shows the string corresponding to a specific trigger.

 

 

CL GPIO TRANsmit <trigger #>

Clears the transmit string for a specified trigger

 

 

condition. If an Email alert is triggered for the condition,

 

 

no text will be included in the alert.

 

 

<trigger #> is 1-16, and indicates the trigger condition

 

 

for which the string is being cleared.

 

 

NOTE: If a new trigger condition is set, all undefined

 

 

trigger conditions are reset to their default value.

Example:

 

 

Local> show gpio tran

 

Trig #

Email String

 

------

------------

 

0:

GPIO #1 is 1

 

1:

GPIO #2 is 1

 

Local> set gpio tran 0 your email text msg here

Local> show gpio tran

 

Trig #

Email String

 

------

------------

 

0:

your email text msg here

1:

GPIO #2 is 1

 

Local> show gpio tran 1 1: GPIO #1 is 1