Table 3-16.Current and Power Requirements (SCSI Interface)

Functional SpecificationsSDLT 600 Product Manual

Table 3-16.Current and Power Requirements (SCSI Interface)

 

5 V Current (A)

 

12 V Current (A)

 

DC Power (W)

AC Power (W)

Mode

MaxPk1

 

MaxPk1

 

Max4

 

Max6

 

 

MaxMean2

Typ3

 

MaxMean2

Typ3

 

Typ5

 

Typ7

 

 

 

 

 

 

 

 

 

 

 

 

 

Standby/Idle

2.6

 

2.6

 

2.4

0.2

 

0.1

 

0.1

14

14

47

45

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Media Loading/

6.2

 

5.3

 

3.4

2.7

 

0.9

 

0.7

30

26

64

56

Unloading

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

600 Write–

4.3

 

4.0

 

3.7

1.3

 

0.3

 

0.3

23

22

51

48

Motor Start8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

600 Write–

5.4

 

5.1

 

4.9

0.7

 

0.5

 

0.4

30

30

65

63

Streaming

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max for

n/a

 

5.3

 

n/a

n/a

 

0.9

 

n/a

30

n/a

70

n/a

SDLT 600 tape

 

 

 

 

 

 

 

 

 

 

 

 

 

 

drive Modes9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.The Max-Peak value represents short current spikes drawn for durations of < 50ms. On the 12V supply, the peaks correspond to the pulse-width-modulated switching of the motors. These values are calculated from the average of Peak-ripple-current + 2 sigma, measured at nominal DC voltage.

2.The Max-Mean value is the average of the maximum RMS current drawn during this operating mode. These values are calculated from the average of RMS current + 3 sigma, measured at nominal DC voltage.

3.The typical current is calculated from the average of all RMS current drawn during this operating mode, measured at nominal DC voltage.

4.The Max DC power is calculated from the typical DC power + 3 sigma, measured at nominal DC voltage. This value takes into account that the peak currents on the 5V and 12V do not occur at the same time.

5.The Typical DC power is calculated from the average RMS DC power drawn during this operating mode, measured at nominal DC voltage. This value also takes into account that the peak currents on the 5V and 12V do not occur at the same time.

6.The Max AC power is calculated from the typical AC power in tabletop tape drives + 3 sigma.

7.The Typical AC power is calculated from the average of AC power drawn in tabletop tape drives.

8.These events last < 1 second and occur at a duty cycle of less than 25%.

9.The Max values for each mode are based on the Max-Mean values, since the peak values are of very short duration.

(Common Notes)

(1) Voltage tolerance: 5V ±5%, 12V ±5%; Room temperature 24 °C. AC power measured at 117 V, 60 Hz.

(2) DC Current, MaxMean, and DC/AC Power Max refer to the statistically calculated maximum average requirement based on a sample population of tape drives. These values do not reflect the peak current or power requirement; this amount is given by the DC MaxPk current.