Cleaning the Tape Mechanism

SDLT 600 Product Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: If the tape drive is mounted in a tape automation library, the CUP/FUP data cartridge rewinds to BOT and unbuckles in preparation for unloading, but does not automatically eject.

5.3.4Firmware (Code) Update Troubleshooting

Try these remedial actions if the tape drive’s code update fails:

Updating the same revision

If you request a code update that is the same as the code revision already on the tape drive, the system updates the controller code but not the servo-specific code. The steps for this type of update are the same as for a normal update.

Updating fails, which causes the tape drive to be reset; the problem can result from any of the following circumstances:

Data cartridge contains incompatible update image.

Data cartridge does not contain an update image.

No data cartridge in the tape drive.

5.4Cleaning the Tape Mechanism

This section discusses the SDLT 600 tape drive cleaning tape, maintenance considerations, and important compatibility issues you need to be aware of.

NOTE: When your backup software indicates needed cleaning, or the yellow LED on the tape drive comes on, use the SDLT CleaningTape to clean the unit. Do not clean the tape drive unless the tape drive specifically indicates cleaning is necessary.

5-6

March 2004

81-81184-02 REV A01

Page 80
Image 80