4.4.2Configuring the Internal Tape Drive for TERMPWR

SDLT 600 Product Manual

Chapter 4: Installing Your Tape Drive

4.4.2Configuring the Internal Tape Drive for TERMPWR

You must terminate a SCSI bus at each end of the bus. Terminate all signals not defined as RESERVED, GROUND, or TERMPWR exactly once at each end of the bus. At least one device must supply terminator power (TERMPWR).

To enable TERMPWR, install the jumper across Pins 1 and 2 (see Figure 4-3) on the TERMPWR jumper block. Remove the jumper to disable TERMPWR. Pins 3 and 4 on this block are reserved and require no jumper.

TERMPWR Block (4 pin)

Pin 1

(Install jumper on Pins 1-2 to enable TERMPWR)

Pin 2

Figure 4-3.TERMPWR Jumper Block on Rear of Tape Drive

4.4.3Installing the Internal Tape Drive

“Securing the Internal Tape Drive” on page 4-10describes installing the tape drive by securing the tape drive in its bay or chassis and connecting the SCSI bus (or Fibre Channel) and power cables. When you have finished mounting and installing the tape drive, proceed directly to “Confirming the Installation” on page 4-25to confirm the installation.