Troubleshooting

SDLT 600 Product Manual

 

 

5.6Troubleshooting

The following subsections provide troubleshooting information that might be helpful should the system fail its Power-On Self-Test (POST).

Refer to the data cartridge appendices in this manual (Appendix A, “Super DLTtape I and

Super DLTtape II Data Cartridges” and Appendix B, “DLTtape VS1 Data Cartridge”) for complete visual inspection instructions for Super DLTtape I & II, and DLTtape VS1 data cartridges.

The web site http://www.dlttape.com also includes valuable information about SDLT systems.

5.6.1POST Troubleshooting

Table 5-4provides troubleshooting tips that you will find useful in the event that your SDLT 600 tape drive system fails its POST.

If, after attempting the recommended actions listed in the table, the problem still exists or recurs, a hardware failure may be the cause. Contact your service representative.

Table 5-4.Troubleshooting Chart

If…

Then…

You should…

 

 

 

System does not recognize

System may not be configured

Configure system to recognize the

the SDLT 600 tape drive

to recognize the interface ID.

SDLT 600 tape drive system’s ID.

system.

 

 

Interface ID may not be unique.

Change the interface ID and reconfigure the

 

 

 

system. The new ID becomes effective at

 

 

the next power on or interface bus reset.

 

 

 

 

Interface adapter parameters

Check interface adapter documentation.

 

may not be correct.

 

 

 

 

 

Interface signal cable may be

Ensure interface cable is fully seated at each

 

loose.

connector end.

 

 

 

 

Interface terminator may be

Ensure correct, secure termination of bus.

 

loose or not present on the bus.

 

 

 

 

5-12

March 2004

81-81184-02 REV A01

Page 86
Image 86
Tandberg Data 600 manual Post Troubleshooting, If… Then… You should…