Setup Information

Function Tone

Function Tone Duration Field

The Function Tone Duration field identifies the duration, in ms, of the function tone. When dual function tones are set, both tones are set to this duration. In most cases, this value is set to 40ms.

The range for this field is 0 to 999ms.

Function Tone Magnitude Field

The Function Tone Magnitude field identifies the level, in dBm, of the function tone.

The range for this field is -60to 12dB.

FTone 1-16 Frequency Fields

The FTone 1-16 Frequency fields identify the value, in Hz, associated with each function tone burst. If the second value is set at zero (0), no second function tone is sent. The standard function tones and their frequencies are shown in Table 7

The range for this field is 0 to 3200 Hz.

TABLE 7. Standard Function Tone Frequencies

Function Tone

Frequency

Number

(Hz)

 

 

F1

1950

 

 

F2

1850

 

 

F3

1750

 

 

F4

1650

 

 

F5

1550

 

 

F6

1450

 

 

F7

1350

 

 

F8

1250

 

 

Function Tone

Frequency

Number

(Hz)

 

 

F9

1150

 

 

F10

1050

 

 

F11

950

 

 

F12

850

 

 

F13

750

 

 

F14

650

 

 

F15

550

 

 

F16

450

 

 

To define the frequencies and function tones, do the following:

1.From the links, select Tone Frequency & Durations. The Tone Frequency and Durations window appears.

2.From the PTT Frequency drop down menu, select the PTT frequency (in Hz).

3.In the Guard Tone Duration field, enter the amount of time (in ms) the guard tone plays before the function tone.

4.In the Guard Tone Magnitude field, enter the level (in dBM) of the guard tone.

5.In the Hold Tone Magnitude field, enter the level (in dBM) of the hold tone summed with TX audio to keep the radio in a transmit state.

6.In the Hold Tone Hangtime field, enter the amount of time (in ms) the hold tone continues after the release of the PTT button.

7.In the Function Tone Duration field, enter the duration (in ms) of the function tone.

8.In the Function Tone Magnitude field, enter the level (in dBM) of the function tone.

114

Page 112
Image 112
Telex IP-223 technical manual 114, Function Tone Duration Field, Function Tone Magnitude Field, FTone 1-16 Frequency Fields