Setup Information

RX Delay Field

The RX Delay field identifies the amount of time, in ms, RX audio is recorded and stored. RX audio is constantly recorded by the IP-223 and when a COR or LAM triggered detect occurs, the IP-223 goes back the specified time of delay to start generating Ethernet packets. This provides the ability to prevent lost first syllables using COR.

The range for this field is 0 to 1000ms.

LAM Setup

LAM Level Field

The LAM Level field identifies the threshold, in dB, at which the radio/line un-mutes and sends RX packets to the Ethernet.

The range for this field is -50 to +10dB.

LAM Time Field

The LAM Time field identifies the amount of time, in seconds, the console continues to play audio when receiving audio above the LAM threshold specified in the LAM Level field. This entry is also used by the Ethernet to determine how long to send audio.

The range for this field is 0 to 60 sec.

Mic Click Setup

Mic Click Call Enabled Check Box

The Mic Click Call Enabled check box indicates whether or not a remote radio user can click the radio PTT a specified number of times within a specified period of time to dial a programmed number. If selected, a remote radio user can click the radio PTT a specified number of times within a specified period and, upon receipt of this sequence, the IP-223 takes the PIB or TDI offhook and automatically dials the number in the Click Dial String field.

Number of Clicks Field

The Number of Clicks field identifies the number of times the radio PTT must be pressed to automatically dial the number in the Click Dial String field.

The range for this field is 1 to 5.

Time Between Clicks Field

The Time Between Clicks field identifies the amount of time, in ms, allowed between mic clicks.

The range for this field is 0 to 9999ms.

Click Dial String Field

The Click Dial String field identifies the number automatically dialed when the radio PTT is pressed the number of times specified in the Number of Clicks field.