53
Multicast Address Setup Window
Outgoing Port Field
The Outgoing Port field identifies the port number where the ring packet is generated. This number must be unique and be
between 1024 and 65535.
NOTE: The ring Multicast Address and port number must match the console’s ring multicast setting to receive the ring
signal.
TTL Field
The TTL (Time-To-Live) field identifies the number of routers the multicast audio packets for the thing to pass through before
being discarded. Network design dictates this value. See your network administrator for further information.
This field range is 0–128, the default value is 6.
Enable Check Box
The Enable check box is used to enable communication with TSM (Telex System Manager). If unselected, TSM can not
detect the IP-223. By default, the check box is selected. TSM is used to update IP-223 firmware. To learn how to update
IP-223 firmware, see “Update Firmware” on page 111. See the Telex System Manager technical manual for operation details.
Name Field
The Name field displays Sys Manager and is not editable.
Multicast Address Field
The Multicast Address field displays the default Multicast Address used by TSM to detect connected VoIP hardware. This
value is not editable.
Incoming Port Field
The Incoming Port field identifies the port used to communicate with TSM. TSM requests data from the IP-223 through this
port. This field is automatically populated and is not editable.
Outgoing Port Field
The Outgoing Port field identifies the port used to communicate with TSM. The IP-223 sends data through this port to TSM.
This field is automatically populated and is not editable.
TTL Field
The TTL (Time To Live) field identifies the number of routers the multicast audio packets pass through before being
discarded. The value in this field is entered by default and used by TSM to communicate with VoIP hardware. This value is not
editable.
The range for this field is 1 to 128.
Enable Check Box
The Enable check box is used to setup a tape recorder for the specified line.
System Manager Setup