Texas Instruments TNETX4090 specifications Physical medium attachment interface port Receive

Models: TNETX4090

1 78
Download 78 pages 14.04 Kb
Page 62
Image 62

TNETX4090

ThunderSWITCH II9-PORT 100-/1000-MBIT/S ETHERNETSWITCH

SPWS044E ± DECEMBER 1997 ± REVISED AUGUST 1999

physical medium attachment interface (port 8)

receive

PMA receive (see Figure 16)

NO.

 

 

MIN

MAX

UNIT

 

 

 

 

 

 

1

tc(Mxx_RBC)

Cycle time, receive byte clock 0 and 1 (Mxx_RCLK, Mxx_COL)

16

16

ns

±

t

Drift rate² of receive bye clock 0 and 1

0.2

 

ns

 

drift(Mxx_RBC)

 

 

 

 

2,3

tw(Mxx_RBC)

Pulse duration, Mxx_RCLK, Mxx_COL low or high

40%

60%

ns

4

tsu(Mxx_RXD)

Setup time, Mxx_RXD7±Mxx_RXD0 valid before Mxx_RCLK/COL

2.5

 

ns

4

tsu(Mxx_RXDV)

Setup time, Mxx_RXDV valid before Mxx_RCLK/COL

2.5

 

ns

4

tsu(Mxx_RXER)

Setup time, Mxx_RXER valid before Mxx_RCLK/COL

2.5

 

ns

5

th(Mxx_RXD)

Hold time, Mxx_RXD7±Mxx_RXD0 valid after Mxx_RCLK/COL

1.5

 

ns

5

th(Mxx_RXDV)

Hold time, Mxx_RXDV valid after Mxx_RCLK/COL

1.5

 

ns

5

th(Mxx_RXER)

Hold time, Mxx_RXER valid after Mxx_RCLK/COL

1.5

 

ns

6

tskew(Mxx_RBC)

Skew between receive byte clock 1 and receive byte clock 0

7.5

8.5

ns

²tdrift is the (minimum) time for either RBC0 or RBC1 to drift from 63.5 MHz to 64.5 MHz or 60 Mhz to 59 MHz from their lock value. It is applicable under all input signal conditions (except under certain circumstances during comma detection), including invalid or absent input signals, if the receiver clock recovery unit was previously locked to Mxx_RFCLK or to a valid input signal.

 

1

 

 

6

 

2

3

5

 

 

4

Receive Byte

Clock 0

Receive

Code Group

Comma Detect

Receive Byte

Clock 0

Figure 16. PMA Receive

4

5

Data Group

62

POST OFFICE BOX 655303 DALLAS, TEXAS 75265

Page 62
Image 62