4.26 Fluorescent lamp

4 Replacement Procedures

4.26 Fluorescent lamp

This system uses the following LCD module.

Type

Part No.

Supplier

Section

 

 

 

 

15.4 inch

G33C0002A110

Samsung

4.26.1

(W-XGA)

 

 

 

 

 

 

 

NOTE: - When working with a LCD module, always use a flat, grounded table.

-Handle the backlight unit in the environment without dust, such as on the clean bench. Keep the worktable free from any screws or other material that may scratch the LCD surface.

-Use an anti-static or protective sheet.

-When replacing the FL unit, cover with a finger protector or similar to prevent dirtying or scratching the LCD panel.

-Take care when handling the lamp. Excessive force may break the lamp.

-Ensure always that the power of the LCD module is turned off before connecting or disconnecting cables and connectors.

4-70