EXP1240 System Installation Guide

Revision 06

Configuring the Primary Base Station

You will need to perform the following steps on the primary base station only. See page 33 for information on all other base stations.

1)Place the primary base station at its final location. (See the Network Planning Guide for information on the proper placement of base stations.)

2)Login to the base station.

3)In the left hand panel, click on Multi cell. This opens the Multi-cellscreen.

Figure 22: Multi-cellscreen (default values)

4)Set the Multi cell system field to Enable.

5)In the System chain ID field, enter the unique identifier of the chain this base station should belong to. Acceptable ID values range from 0 to 99999.

6)In the Synchronization time(s), change the number of seconds between each time this base station re-synchronizes with the other base stations in this chain (if necessary).