EXP1240 System Installation Guide Revision 06
© 2013 Uniden America Corp. PROPRIETARY AND CONFIDENTIAL Page 35 of 71
The IP Status field of the base station you are logged into should show This
unit. Any other base stations in this chain should show Connected (i.e.,
connected to the network and functioning properly) as their IP status. If any
base station shows Connection Loss as its IP status, that base station is not
connected to the network or has lost power.
The primary base station always serves as its own sync source, so the DECT
sync source field should display Primary:RPN{its own RPN}. The DECT
Property field shows Primary.
This base station's DECT sync source will show (any) RPN and its DECT
Property field will show Locked.
Check the DECT sync source drop-down box for this base station to verify
that there is a selection for the primary base station with a dBm value. If
there is not a dBm value, wait for the system to further synchronize
(approximately 2 minutes). When there is a dBm value, select the primary
base station from the DECT sync source drop-down box and click Save.
If the primary base station is not on the list or if the signal strength is below -
70 to -73 dBm (-74dBm or less), move this base station to a different
location. (You could also configure the other Level 1 base stations first and
then come back and configure this one at Level 2.)
The DECT Chain appears at the bottom of the display and shows the
synchronization source for all base stations in this system. Until the primary
base station is selected as the DECT sync source, there will be a warning in
the DECT Chain for this base station.
Figure 26:
Base Station Group
table, synchronization complete (
Multi-cell
screen)
13) When the system has finished synchronizing, repeat this process for each base station at
Level 1.