EXP1240 System Installation GuideRevision 06

Figure 27: Base Station Group table, Level 1 complete (Multi-cellscreen)

Configuring Base Stations at Level 2 and Up

1)Place the first Level 2 base station at its final location. (See the Network Planning Guide for information on the proper placement of base stations.)

2)Login to the base station.

3)Reset the base station to its default settings (open the Management screen and click Default Base Station). If this base station has never been configured, skip this step.

4)Go to the Multi-cellscreen and set the Multi cell system field to Enable.

5)Enter the System chain ID and select a Multi Cell debug setting only if necessary.

6)Click Save and reboot the base station.

7)Allow several minutes for the base station to reboot, then go back to Multi-cellscreen and check the Base Station Group table.