Recommended test equipment

The test equipment recommended for acceptance testing is shown below. Alternative equipment may be used provided it complies with the stated minimum specification.

Recommended test equipment

Description

Minimum specification

Example

 

 

 

Power meter

±0.1 dB from 9 kHz to 2.4 GHz

IFR 6960B with

 

 

6932 sensor

Measuring receiver

0 dBm to 127 dBm; 2.5 MHz to 2.4 GHz Capable

Agilent 8902A with

 

of measuring residual FM less than 2 Hz and SSB

option 037 * and

 

11722A sensor and

 

phase noise < 124 dBc/Hz at 20 kHz offset from a

11793A down

 

1 GHz carrier

 

 

converter

Signal generator

+8 dBm from 32.5 MHz to 2.43 GHz

IFR 2041

Frequency counter

10 Hz to 2.4 GHz

Agilent 53181A

 

 

with option 030

Audio analyzer

Capable of measuring THD of 0.01% from 100 Hz

Rohde & Schwarz

 

to 20 kHz

UPA3

Spectrum analyzer

DC to 7.2 GHz, 3 Hz resolution bandwidth

Anritsu MS2602A

Modulation meter

AM, FM and ΦM 50 kHz to 2.4 GHz, Accuracy ±1%

IFR 2305 plus

 

at 1 kHz modulation frequency

distortion option **

Function generator

DC to 100 kHz sine, ±0.6 dB flatness, 100 kHz

Agilent 3325B

 

square wave

 

Digital voltmeter

DC voltage measurement

Solartron 7150+

50 load

1 W, 50 nominal impedance, DC to 2.4 GHz

Lucas Weinschel

(termination)

 

M1404N

Oscilloscope

100 MHz bandwidth

Tektronix TDS 220

 

 

 

Personal Computer with Microsoft Windows version 3.1 (or greater) installed and fitted with National Instruments PCIIA GPIB Interface Card

Vero 203-304014B VXI Mainframe Racal 1260-00C GPIB Slot 0

IFR 3002 executable Soft Front Panel, part number 59000-286

*Option 037 is necessary to measure SSB phase noise.

**The distortion option of the 2305 Modulation Meter allows modulation distortion tests to be carried out with greater ease. If a 2305 with the distortion option is not available, the audio analyzer may be connected to the modulation meter LF output and set to measure distortion.

Executable soft front panel software

The acceptance test procedures use the supplied executable soft front panel as the user interface for the 3002 VXI Signal Generator.

5-2

Page 77
Image 77
VXI 3002 manual Recommended test equipment, Executable soft front panel software