WARNING |
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
DETERGENT DISPENSER | INLET VALVE SOLENOIDS |
MOTOR & SWITCH |
|
Refer to page
1.Unplug washer or disconnect power.
2.Disconnect the detergent dispenser mo- tor and switch connector from the CCU.
3.Set the ohmmeter to the R x 100 scale.
4.Touch the ohmmeter test leads to the indicated wire connector terminals. The meter should indicate as follows:
Dispenser motor at pins 1 and 3 = 1400 to 1600 Ω.
Dispenser switch at pins 5 and 6 = 0 Ω
65 3 1
(Connector viewed From Wire End)
COLD HOT
Refer to page
1.Unplug washer or disconnect power.
2.Disconnect the inlet valve solenoid con- nector from the CCU.
3.Set the ohmmeter to the R x 100 scale.
4.Touch the ohmmeter test leads to the indicated wire connector terminals. The
meter should indicate between 750 and 850 Ω.
7 5 3 1
(Connector viewed From Wire End)