WARNING |
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
DRAIN PUMP MOTOR | INTERFERENCE FILTER |
Motor
Terminals
Refer to page
1.Unplug washer or disconnect power.
2.Disconnect the drain pump motor connec- tor from the CCU.
3.Set the ohmmeter to the R x 1 scale.
4.Touch the ohmmeter test leads to the two
drain pump motor connector pins. The meter should indicate 15 Ω.
Refer to page
1.Unplug washer or disconnect power.
2.Disconnect the wire connectors from the interference filter terminals.
3.Set the ohmmeter to the R x 10K scale.
4.Touch the ohmmeter test leads to the interference filter connector pins. The
meter should indicate approximately 450K Ω.
2 1
(Connector viewed From Wire End)