WARNING |
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
HEATING ELEMENT &
TEMPERATURE SENSOR
Heating
Element
Temperature
Sensor Connector
Refer to page
1.Unplug washer or disconnect power.
2.Disconnect the wire connectors from the heating element and temperature sensor terminals.
3.Set the ohmmeter to the R x 1 scale.
4.Touch the ohmmeter test leads to the two
heating element terminals. The meter should indicate between 10 and 20 Ω.
5.Disconnect the heating element tempera- ture sensor connector from the CCU.
6.Touch the ohmmeter test leads to the two temperature sensor connector terminals. The meter should indicate as shown in the following chart.
Temperature | Results |
|
|
| ||
32°F (0°C) | 35.9K ohms |
|
|
| ||
|
|
| ||||
86°F (3°C) | 9.7K | ohms |
|
|
| |
104°F (40°C) | 6.6K | ohms |
|
|
| |
2 | 1 | |||||
|
|
| ||||
122°F (50°C) | 4.6K | ohms | ||||
|
|
| ||||
|
|
|
|
|
| |
140°F (60°C) | 3.2K | ohms |
|
|
| |
|
|
|
|
|
| |
158°F (70°C) | 2.3K | ohms |
|
|
| |
|
|
|
|
| ||
203°F (95°C) | 1K ohms |
|
|
|