Whirlpool MFW 9700S, MFW 9600S manual Removing the Flowmeter

Models: MFW 9600S MFW 9700S

1 88
Download 88 pages 5.02 Kb
Page 42
Image 42

REMOVING THE FLOWMETER

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

1.Unplug washer or disconnect power.

2.Turn off the water supply to the washer.

3.Remove the top cover and the console (see page 4-2 for the procedures).

Flowmeter

4.Loosen the two clamps and remove the two hoses from the ends of the flowmeter.

5.Disconnect the wire connector from the flowmeter.

Flowmeter

Wire Connector

4-7