DIAGNOSTIC TEST

The washer must be empty and the control must be in the OFF state before pressing the touchpad sequence to start the test.

Starting the Test Mode

Close the door.

Push CONTROL/ON (if present on this model).

Select the DRAIN/SPIN cycle.

Select NO SPIN by pressing the SPIN SPEED touchpad.

Push PREWASH OPTION four times within five seconds. (If PREWASH OPTION is not present on this model, press RINSE HOLD four times within five seconds.) C:00 will light up on the display.

If the Starting procedure fails, push the PAUSE/CANCEL touchpad, then repeat the starting procedure.

Test Program Control

In order to advance to the next step of the test procedure, push PREWASH OPTION touchpad two times. If PREWASH OPTION is not present on this model, press RINSE HOLD two times.

Indication

Control Action

Actuators To Be Checked

 

 

 

C:00

Door locks.

• Door lock system

 

 

 

C:01

Fill by cold water inlet valve.

• Flowmeter

• Cold water inlet valve

 

 

C:02

Distribution system is set to Prewash position.

• Dispenser motor

 

 

• Dispenser contact

 

 

 

C:03

Fill by hot water inlet valve.

• Hot water inlet valve

 

 

 

C:04

Drum rotates clockwise at wash speed.

• Motor

• Motor Control (MCU)

 

 

 

 

 

C:05

Heater (if present on this model) is switched ON.

• Heater (if present on this model)

 

Drum rotates clockwise at wash speed.

• NTC

 

If there is not enough water in the tub, the water inlet

 

 

valve will be switched ON to achieve the minimum

 

 

water volume.

 

 

 

 

C:06

Drain pump is ON.

• Drain pump

 

 

 

C:07

Drum rotates counterclockwise from 35 to 90 rpm

• Motor

 

within 15 seconds.

• Motor Control (MCU)

 

 

 

C:08

Drum rotates counterclockwise at maximum speed.

• Motor

 

- If max. speed =EXTRA HIGH, drum speed =

• Motor Control (MCU)

 

>1000 rpm.

 

 

- If max. speed =HIGH, drum speed = >800

 

 

rpm.

 

 

 

 

6-8

Page 78
Image 78
Whirlpool MFW 9700S, MFW 9600S manual Diagnostic Test, Starting the Test Mode, Test Program Control