6. Printer specifications and requirements
This chapter provides power and space requirements for your 96/4635/180 printer. It also provides printer environmental specifications.
For facts about controller power and space requirements, refer to the “Controller specifications and requirements” chapter of this guide.
Power requirements
Your 96/4635/180 printer has important power requirements that must be accommodated. These requirements are summarized in the table below. For further details on power requirements, refer to the voltage charts and wiring diagrams that follow.
For details on controller power requirements, refer to the “Controller specifications and requirements” chapter of this guide.
Table
|
|
| Amp. |
|
|
| Printer | Voltage | service | KVA rating | NEMA |
|
|
|
|
|
|
Printer — 60 Hz | 180 | 120/240 VAC or 120/208 VAC | 50 amp | Operating: 7.3 | |
(U. S. and Canada) | (Dual | (Cord 1) | (Cord 1) | + .75 per middle | (Cord 1) |
| cords) | 120/240 VAC or 120/208 VAC | 30 amp | module stacker | |
|
| (Cord 2) | (Cord 2) |
| (Cord 2) |
|
|
|
|
|
|
| 96/4635 | 120/240 VAC or 120/208 VAC | 50 amp | Operating: 7.3 | |
|
|
|
| + .75 per middle |
|
|
|
|
| module stacker |
|
|
|
|
|
|
|
Printer— 50 Hz | 180 | 220, 230, 240 VAC | 30 amp | Consult local |
|
DELTA | 4635 | (3 phase, 4 wire) |
| service rep. |
|
| 96 |
|
|
|
|
|
|
|
|
|
|
WYE | 180 | 380, 400, 415 VAC | 20 amp | Consult local |
|
(Star) | 4635 | (3 phase, 5 wire) |
| service rep. |
|
| 96 |
|
|
|
|
|
|
|
|
|
|
|
| Agency certification: UL 478 and 1950, IEC 950, CE Mark, | |||
|
| CSA 22.2 |
XEROX DOCUPRINT NETWORK PRINTER SERIES INSTALLATION PLANNING GUIDE FOR MODELS 96/4635/180 NPS |