PRINTER SPECIFICATIONS AND REQUIREMENTS

Outlet configurations

This section discusses specifications for system outlets and the required wall outlet configurations for the USA / Canada and internationally.

Note: All power outlets must be dedicated to this equipment. When determining the electrical connections for your printer, make sure that:

Each power cord has a separate circuit

The printer power cord configurations match your receptacle

Your electrical outlets are within the required specifications.

50 Hz systems: Ensure that power connections are per local codes/ regulations.

Printer outlet voltages—60 Hz

The following table shows the voltages for the outlets on your printing system. All power outlets must have a dedicated circuit for each system equipment piece. Make sure each power cord has a separate circuit.

Table 6-2.Printer (60 Hz) voltage requirements at power outlet

Service outlet

 

 

 

configuration

Measurement of wiring

Nominal

Range

 

 

 

 

4 Wire

Line 1 to neutral

120 V RMS

107-127 V RMS

 

 

 

 

4 Wire

Line 2 to neutral

120 V RMS

107-127 V RMS

 

 

 

 

4 Wire

Neutral to ground

0

0-10 V RMS

 

 

 

 

4 Wire

Line 1 to line 2

208 V RMS

182-220 V RMS

 

 

 

 

4 Wire

Line 1 to line 2

240 V RMS

210-254 V RMS

 

 

 

 

6-2

XEROX DOCUPRINT NETWORK PRINTER SERIES INSTALLATION PLANNING GUIDE FOR MODELS 96/4635/180 NPS

Page 62
Image 62
Xerox 180 NPS manual Outlet configurations, Printer outlet voltages-60 Hz