
PRINTER SPECIFICATIONS AND REQUIREMENTS
Printer outlet voltages—50 Hz
All power outlets must have a dedicated circuit for each system equipment piece. Make sure each power cord has a separate circuit.
Note: Consult with your service representative to determine the type of plug and receptacle to be used for your 50 Hz system.
DELTA
voltages at the power source.
Table
Service outlet |
|
|
|
configuration | Measurement | Nominal | Range |
|
|
|
|
4 Wire 220 V | Line 1 to line 2 | 220 V RMS | |
|
|
|
|
4 Wire 220 V | Line 2 to line 3 | 220 V RMS | |
|
|
|
|
4 Wire 220 V | Line 1 to line 3 | 220 V RMS | |
|
|
|
|
4 Wire 230 V | Line 1 to line 2 | 230 V RMS | |
|
|
|
|
4 Wire 230 V | Line 2 to line 3 | 230 V RMS | |
|
|
|
|
4 Wire 230 V | Line 1 to line 3 | 230 V RMS | |
|
|
|
|
5 Wire 240 V | Line 1 to line 2 | 240 V RMS | |
|
|
|
|
5 Wire 240 V | Line 2 to line 3 | 240 V RMS | |
|
|
|
|
5 Wire 240 V | Line 1 to line 3 | 240 V RMS | |
|
|
|
|
WYE (or Star)
Table
Service outlet |
|
|
|
configuration | Measurement | Nominal | Range |
|
|
|
|
5 Wire 415 V | Line 1 to line 2 | 415 V RMS | |
|
|
|
|
5 Wire 415 V | Line 2 to line 3 | 415 V RMS | |
|
|
|
|
5 Wire 415 V | Line 1 to line 3 | 415 V RMS | |
|
|
|
|
5 Wire 415 V | Line 1 to neutral | 240 V RMS | |
|
|
|
|
5 Wire 415 V | Line 2 to neutral | 240 V RMS | |
|
|
|
|
5 Wire 415 V | Line 3 to neutral | 240 V RMS | |
|
|
|
|
XEROX DOCUPRINT NETWORK PRINTER SERIES INSTALLATION PLANNING GUIDE FOR MODELS 96/4635/180 NPS |