PRINTER SPECIFICATIONS AND REQUIREMENTS
Environmental specifications
When you select a site location for your DocuPrint printer, avoid environments with extreme variations in temperature and other hazards, such as excessive dust or humidity. Recommended environmental ranges for the work area are as follows:
Table
Condition |
| Range |
|
|
|
Operating | Recommended: | 68° F to 76° F / |
temperature: |
| 20° C to 24° C |
| Minimum: | 50° F / 10° C |
| Maximum: | 85° F / 29° C |
|
|
|
Humidity: | Recommended: | 45% ±10% |
| Minimum: | 30% |
| Maximum: | 65% |
|
| |
Altitude: | Normal: Up to 6,000 feet / 1,830 m | |
|
| above sea level |
| Maximum: | 9,000 feet / 2,743 m above |
|
| sea level. |
|
|
|
Heat dissipation: |
|
|
96 and 4635 | Operating: | 28,140 BTU/hour |
Standby: | 4,454 BTU/hour | |
| Energy Saver: | 2,700 BTU/hour |
180 | Operating: | 32,770 BTU/hour |
Standby: | 4,454 BTU/hour | |
| Energy Saver: | 2,700 BTU/hour |
|
|
|
Audible noise: | Operating: |
|
| Continuous: | 82 dB(A) |
| Impulse: | 82 dB(A) |
| Standby: |
|
| Continuous: | 52 dB(A) |
| Impulse: | N/A |
|
|
|
XEROX DOCUPRINT NETWORK PRINTER SERIES INSTALLATION PLANNING GUIDE FOR MODELS 96/4635/180 NPS |